Skip to content

New: dBlue

Sound-insulating drainage system

Certified quality

Technical data

Material PP-MD mineral-reinforced (pipes and fittings)
color Blue, RAL 5012
Pipe dimensions DN 50, DN 75, DN 90, DN 110
Area of application Non-pressurized domestic wastewater with pH value 2 -12
Application code BD: Inside and below the building structure
Temperature resistance Continuous load: 90°C
Short-term: 95°C
Min. processing temperature -10°C
Density Pipes: 1.1 -1.3 g/cm³
Fittings: 1.1 -1.4 g/cm³
Coefficient of linear expansion 0.10 mm/mK
Ring stiffness 4.0 kN/m² (SN4)
Seals SBR according to DIN EN 681-1
Sound behavior according to DIN EN 14366 P-BA 124/2020: 16 dB(A) at 4 l/s (with dBlue clamp)
Fire behavior B2 (normal flammability) in accordance with DIN 4102
E (normal flammability) in accordance with EN 13501-1
Proof of usability abZ Z-42.1-399: General building authority approval (DIBt)
Tests System test based on DIN EN 1451-1
"Ice crystal" in accordance with DIN EN 1451 and DIN EN 1411